24VDC 4A Single Output Industrial DIN Rail Power Supply
Model:PSDR24V4A2

Overview

The PSDR24V4A is a 24VDC Class II DIN rail mount switching power supply, designed with a fully isolated plastic case to prevent user contact and the risk of shock. Features no load power consumption to save energy and protection against short circuit, over load, over voltage & over temperature.

Product features:
• 24VDC 4A Power output with universal 88~264VAC input
• Adjustable voltage range 24 ~ 25.5V; tailor voltage in longer cable runs
• Integrated protection against line overvoltage / overload / short circuit
• Integrate to protect IT & security in home, office and retail environments
• Designed for installation on DIN rail TS-35/7.5 or 15
• Prevents overheating with free air convection
• Double Insulated - Isolation Class II
• LED indicator for power on
• No load power consumption (<0.3W)
Specifications
AC Current 3A/115VAC / 1.6A/230VAC
Current Range 0 ~ 4.2A
DC Voltage 24V
Dimensions 70 x 90 x 54.5mm
Efficiency 90%
EMI Conduction & Radiation Compliance to EN61204-3
EMS Immunity Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
Frequency Range 47 ~ 63Hz
Harmonic Current Compliance to EN61000-3-2,-3
Hold Up Time 50ms/230VAC / 18ms/115VAC at full load
In-rush Current Cold Start - 35A/115VAC / Normal - 70A/230VAC
Isolation Resistance I/P-O/P:>100M Ohms/500VDC 25°C 70%RH
Line Regulation ±1.0%
Load Regulation ±1.0%
MTBF 486K hrs min., MIL-HDBK-217F (25°C)
Overload Protection 105 ~ 150% rated output power
Overvoltage Protection 30 ~ 36V
Rated Current 4.2A
Rated Power 100.8W
Ripple and Noise (max.) 150mVp-p
Safety Standards UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 approved; Design refer to EN50178,TUV EN60950-1
Setup, Rise Time 500ms, 60ms/230VAC / 500ms, 60ms/115VAC at full load
Storage Temp., Humidity -40 ~ +85°C , 10 ~ 95% RH
Temp Coefficient ±0.03%/0C (0 ~ 50°C)
Vibration (Component) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Vibration (Mounting) Compliance to IEC60068-2-6
Voltage Adj. Range Pass LPS: 24 ~ 25.5V / Non LPS: 21.6 ~ 29V
Voltage Range 88 ~ 264VAC (277VAC operational) / 124 ~ 370VDC (390VDC operational)
Voltage Tolerance ±1.0%
Withstand Voltage I/P-O/P:3KVAC
Working Humidity 20 ~ 90% RH non-condensing
Working Temperature -30 ~ +70°C
Warranty (Years) 1